• News
  • About Air
    • Wellbeing
      • Sick Building Syndrome
      • Indoor air pollutants & their effects
      • Airborne particles
      • Dangerous fungi
      • The Working Environment
      • Sick Building Syndrome Checklist
      • Legionnaires’ Disease
    • Air Standards
      • IANZ
      • Indoor air quality regulations
  • Services
    • Indoor Air Quality
      • Cooling Tower Testing
      • Microbial Contamination
      • Monitoring the Indoor Environment
    • Medical and laboratory
      • Clean rooms
      • Cytotoxic Drug Safety Cabinets
      • Decontamination
      • Fume cupboard tests
      • HEPA filter testing
      • Laminar flow clean workstations
    • HVAC
      • Airflow balancing
      • Building Warrant of Fitness
      • Datalogging
      • Duct leakage testing
      • Hot-smoke testing
      • Operation and maintenance manuals for heating, ventilating and air conditioning systems
      • Stairwell pressurisation
      • Waterflow balancing
  • Projects
  • Downloads
  • Contact
    • Locations
    • Staff Contacts
    • Enquiry Form
    • Job Vacancies

You are here: Home » Services » HVAC » Stairwell pressurisation

Stairwell pressurisation

Overview

Research clearly shows that when a fire occurs in a multi-compartmented building, the smoke from the fire is a far greater hazard to the occupants than the fire itself. Smoke can kill by asphyxiation or poisoning well before the temperature of the fire or smoke causes injury. Smoke also obscures vision, preventing occupants from finding safe escape routes and hindering the fire brigade’s search and rescue operation.

A key part of fire safety measures is to pressurise areas used as escape (namely stairwells) to prevent smoke entering the area. The design of these systems is complicated, because as people enter and leave the stairwell during an emergency there is an intermittent loss of effective pressurisation. The system supply fan should have sufficient capacity to provide effective pressurisation and prevent smoke entering the stairwell. Balancing this there should also be a method of preventing over-pressurisation, which makes doors difficult to open.

Regulations

The building code states that stairwell pressurisation systems should include supply air rates, required and minimum allowable maximum pressurisation and minimum air velocity through open stair doors. Multi compartment buildings in New Zealand must also comply with the Australian and New Zealand Standard AS/NZS 1668.1:1998. In the Building Code regulation AS 1851.6 refers to the frequency of maintenance routines. It recommends that testing of stairwell pressurisation systems should be completed annually.

Airlab Solution

Airlab is an Independent Qualified Person (IQP) certified for Escape Route Pressurisation Systems under the Territorial Authorities of the Auckland and Wellington Regions and so are both qualified and certified to test these systems.



Services

  • Indoor Air Quality
    • Monitoring the Indoor Environment
    • Cooling Tower Testing
    • Microbial Contamination
  • Medical and laboratory
    • Clean rooms
    • Laminar flow clean workstations
    • Cytotoxic Drug Safety Cabinets
    • HEPA filter testing
    • Fume cupboard tests
    • Decontamination
  • HVAC
    • Airflow balancing
    • Waterflow balancing
    • Datalogging
    • Stairwell pressurisation
    • Hot-smoke testing
    • Building Warrant of Fitness
    • Duct leakage testing
    • Operation and maintenance manuals for heating, ventilating and air conditioning systems

latest news

HEPA filter testing

HEPA filter testing is a new service offered by Airlab. More information on this coming soon.

Read more


 

latest projects

Click here to view information and updates about our existing and past client projects
Read more
subscribe to our news or subscribe to comments
Copyright © 2012 Airlab. All Rights Reserved. Admin